TROUBLESHOOTING AND REPAIR

F-32

 

MAIN INVERTER BOARD POWER FACTOR SECTION TEST (continued)

FIGURE F.14 – LOCATION ON MAIN BOARD

MAIN BOARD

TOC

TOC

PROCEDURE

1.Remove input power to the V205-T machine.

2.Using a phillips head screwdriver, remove the case wraparound cover.

3.Perform the Capacitor Discharge Procedure detailed earlier in this section.

4.Locate the power factor section on the main board and associated plugs. Do not remove plugs from the board. See Figure F.15.

5.Carefully apply the correct input voltage to the V205-T and check for the correct secondary voltages per tables F.10 & F11. Voltage read- ings were taken with a Fluke RMS meter. See Figure F.15 for joint locations.

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

TABLE F.10 – VOLTAGE CHECKS WITH 115 VAC APPLIED TO MACHINE

Generator/Mode

Component

Ref. Point

Value

 

 

 

 

ON/STICK

DD1

A[-],K[+]

250-260 VDC

 

 

 

 

ON/STICK

MF8

S[-],D[+]

125 VDC

 

 

 

 

ON/STICK

MF8

S[-],G[+]

2.2 VDC

 

 

 

 

ON/STICK

MF9

S[-],D[+]

120 VDC

 

 

 

 

ON/STICK

MF9

S[-],G[+]

2.2 VDC

 

 

 

 

ON/STICK

-------

L10 (LED)

ON

 

 

 

 

ON/STICK

TP20-TP9

-------

385 VDC +/-5V

 

 

 

 

 

TABLE F.11 – RESISTANCE CHECKS

 

 

 

 

 

Generator/Mode

Component

Ref. Point

Value

 

 

 

 

OFF

F1

-------

<1 OHM

 

 

 

 

OFF

R82

-------

46 OHM

 

 

 

 