Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-50

TROUBLESHOOTING AND REPAIR

F-50

 

INPUT FILTER BOARD REMOVAL AND REPLACEMENT (continued)

FIGURE F.24 – INPUT FILTER BOARD LOCATION

INPUT FILTER BOARD

PROCEDURE

TOC

TOC

1.Remove input power to the V205-T.

2.Using a phillips head screwdriver remove the case wraparound cover.

3.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.

4.Locate the input filter board. See Figure F.24.

5.Using a 7mm nut driver, label and remove leads R/L1 and S/L2 from the upper right corner of the input filter board. See Figure F.25.

6.Using a 7mm nut driver, label and remove leads RV1 and RV2 from the left side of the main IGBT board. See Figure F.26. See Wiring Diagram

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

FIGURE F.25 – INPUT FILTER BOARD LEADS

R/L1

S/L1

INVERTEC® V205-T AC/DC™

Page 90
Image 90
Lincoln Electric SVM161-A Input Filter Board Removal and Replacement, Figure F.24 Input Filter Board Location