F-42

TROUBLESHOOTING AND REPAIR

F-42

 

SECONDARY OUTPUT BOARD ASSEMBLY TEST (continued)

TABLE F.14 – OUTPUT DIODE RESISTANCE CHECK

MODE

POSITIVE METER

NEGATIVE METER

EXPECTED READING

 

PROBE

PROBE

 

 

 

 

 

MACHINE OFF

TEST POINT A

TEST POINT 3

LOW - LESS THAN 200 OHMS

 

 

 

 

MACHINE OFF

TEST POINT 3

TEST POINT A

HIGH - MORE THAN 1000 OHMS

 

 

 

 

MACHINE OFF

TEST POINT B

TEST POINT 3

LOW - LESS THAN 200 OHMS

 

 

 

 

MACHINE OFF

TEST POINT 3

TEST POINT B

HIGH - MORE THAN 1000 OHMS

 

 

 

 

MACHINE OFF

TEST POINT 2

TEST POINT A

LOW - LESS THAN 200 OHMS

 

 

 

 

MACHINE OFF

TEST POINT A

TEST POINT 2

HIGH - MORE THAN 1000 OHMS

 

 

 

 

MACHINE OFF

TEST POINT 2

TEST POINT B

LOW - LESS THAN 200 OHMS

 

 

 

 

MACHINE OFF

TEST POINT B

TEST POINT 2

HIGH - MORE THAN 1000 OHMS

 

 

 

 

INVERTEC® V205-T AC/DC™

Page 82
Image 82
Lincoln Electric SVM161-A service manual Mode Positive Meter Negative Meter Expected Reading Probe