Lincoln Electric SVM161-A service manual Igbt Inverter Board Test

Models: SVM161-A

1 112
Download 112 pages 28.2 Kb
Page 46
Image 46

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-6

TROUBLESHOOTING AND REPAIR

F-6

 

 

 

 

 

 

 

 

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE AREAS OF

 

RECOMMENDED

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

Error code “E20”, “E24”, or “E25” is

1. Any one of these codes indicates

1.

The Control/Display

Board is

flashing on the digital display.

 

a memory error.

 

faulty. Replace.

 

 

 

 

The machine functions normally

1. Check for obstructions that could

1. Check the fan fuse F3 located on

except the cooling fan does not

 

prevent the fan from turning.

 

the Bus Board Replace if faulty.

operate.

 

 

 

 

 

 

 

 

 

 

2. Perform the Bus Board Test.

 

 

 

 

3. The Main IGBT Inverter Board

 

 

 

 

 

May be Faulty. Perform the

 

 

 

 

 

Main IGBT Inverter Board Low

 

 

 

 

 

Voltage Supply Test.

 

 

 

 

 

 

No High Frequency when the torch

1.

Make sure the HF is in the active

1.

Check fuse F2 on the Bus Board.

trigger is pulled and the machine is

 

mode. See the Set-up Menu in

2.

Check for 385VDC

at Test

in the TIG mode.

 

 

this manual.

 

Points 9 and 20. See the Main

 

 

 

 

 

 

 

 

 

 

IGBT Inverter Board Test.

 

 

 

 

3.

Perform the Control/Display

 

 

 

 

 

Board Test.

 

 

 

 

 

4.

The HF board may be faulty.

 

 

 

 

 

Replace.

 

 

 

 

 

 

 

Error code “E14” is flashing of the

1.

This is an indication that the out-

1.

Check for excessive

welding

digital display

 

 

put inductance is too high.

 

cable length.

 

 

 

 

 

2.

The Main IGBT Inverter Board

 

 

 

 

 

may be faulty.

 

 

 

 

 

3.

The Superimposition Board may

 

 

 

 

 

be faulty.

 

 

 

 

 

4.

The Control/Display Board may

 

 

 

 

 

be faulty.

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

INVERTEC® V205-T AC/DC™

Page 46
Image 46
Lincoln Electric SVM161-A service manual Igbt Inverter Board Test