TROUBLESHOOTING AND REPAIR | ||||||
|
|
|
|
| ||
|
|
|
| |||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
|
| |||
|
|
|
|
|
| |
PROBLEMS |
|
| POSSIBLE AREAS OF |
| RECOMMENDED | |
(SYMPTOMS) |
|
| MISADJUSTMENT(S) |
| COURSE OF ACTION | |
|
|
|
|
|
|
|
|
|
| FUNCTION PROBLEMS |
|
|
|
Error code “E20”, “E24”, or “E25” is | 1. Any one of these codes indicates | 1. | The Control/Display | Board is | ||
flashing on the digital display. |
| a memory error. |
| faulty. Replace. |
| |
|
|
| ||||
The machine functions normally | 1. Check for obstructions that could | 1. Check the fan fuse F3 located on | ||||
except the cooling fan does not |
| prevent the fan from turning. |
| the Bus Board Replace if faulty. | ||
operate. |
|
|
|
|
|
|
|
|
|
| 2. Perform the Bus Board Test. | ||
|
|
|
| 3. The Main IGBT Inverter Board | ||
|
|
|
|
| May be Faulty. Perform the | |
|
|
|
|
| Main IGBT Inverter Board Low | |
|
|
|
|
| Voltage Supply Test. |
|
|
|
|
|
| ||
No High Frequency when the torch | 1. | Make sure the HF is in the active | 1. | Check fuse F2 on the Bus Board. | ||
trigger is pulled and the machine is |
| mode. See the | 2. | Check for 385VDC | at Test | |
in the TIG mode. |
|
| this manual. |
| Points 9 and 20. See the Main | |
|
|
|
|
| ||
|
|
|
|
| IGBT Inverter Board Test. | |
|
|
|
| 3. | Perform the Control/Display | |
|
|
|
|
| Board Test. |
|
|
|
|
| 4. | The HF board may be faulty. | |
|
|
|
|
| Replace. |
|
|
|
|
|
|
| |
Error code “E14” is flashing of the | 1. | This is an indication that the out- | 1. | Check for excessive | welding | |
digital display |
|
| put inductance is too high. |
| cable length. |
|
|
|
|
| 2. | The Main IGBT Inverter Board | |
|
|
|
|
| may be faulty. |
|
|
|
|
| 3. | The Superimposition Board may | |
|
|
|
|
| be faulty. |
|
|
|
|
| 4. | The Control/Display Board may | |
|
|
|
|
| be faulty. |
|
|
|
|
|
|
|
|
CAUTION