QUICK DISCONNECT PLUG (FOR STICK ELECTRODE CABLE and WORK CABLE)

A quick disconnect system is used for the welding cable connections. The stick electrode cable will need to have a plug attached.

1.Cut off welding cable lug, if present.

2.Remove 1.00 in. (25mm) of welding cable insula- tion.

3.Slide rubber boot onto cable end. The boot end may be trimmed to match the cable diameter. Use soap or other nonpetroleum-based lubricant to help slide the boot over the cable, if needed.

BOOT

WELDING CABLE

1.00 in.

25 mm

TRIM, IF REQ'D

TO FIT OVER CABLE

 

4. Insert copper strands into ferrule.

COPPER FERRULE

WELDING CABLE

5.Slide the copper ferrule into the brass plug.

6.Tighten set screw to collapse copper tube. Screw must apply pressure against welding cable. The top of the set screw will be well below the surface of the brass plug after tightening.

SET SCREW

SHIELDING GAS CONNECTION

Obtain the necessary inert shielding gas. Connect the cylinder of gas with a pressure regulator and flow gage. Install a gas hose between the regulator and gas inlet (located on the rear of the welder). The gas inlet has a 5/16-18 right hand female thread; CGA #032.

WARNING

CYLINDER could explode if damaged.

• Keep cylinder upright and chained to a support.

Keep cylinder away from areas where it could be damaged.

Never allow the torch or welding electrode to touch the cylinder.

Keep cylinder away from live electrical cir-

cuits.

___________________________________________

REMOTE CONTROL CONNECTION

A remote control receptacle is provided on the lower center case front of the welder for connecting a remote control to the machine. Refer to the Optional Accessories section of this manual for available remote controls.