Lincoln Electric SVM161-A service manual BUS Board Test, Figure F.11 BUS Board Location

Models: SVM161-A

1 112
Download 112 pages 28.2 Kb
Page 68
Image 68

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-28

TROUBLESHOOTING AND REPAIR

F-28

 

BUS BOARD TEST (continued)

FIGURE F.11 – BUS BOARD LOCATION

BUS BOARD

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

PROCEDURE

1.Remove input power to the V205-T machine.

2.Using a phillips head screwdriver, remove the case wraparound cover.

3.Perform the Capacitor Discharge Procedure detailed earlier in this section.

4.Locate the Bus board and associated plugs. Do not remove plugs from the board. See Figure F.11.

5.Carefully apply the correct input voltage to the V205-T and check for the correct voltages per

Tables F.5, F.6, F.7, F.8 & F.9

6.Machine should be set to “STICK” mode.

INVERTEC® V205-T AC/DC™

Page 68
Image 68
Lincoln Electric SVM161-A service manual BUS Board Test, Figure F.11 BUS Board Location