Lincoln Electric SVM161-A service manual Secondary Output Board Assembly Test

Models: SVM161-A

1 112
Download 112 pages 28.2 Kb
Page 47
Image 47

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-7

TROUBLESHOOTING AND REPAIR

 

F-7

 

 

 

 

 

 

 

 

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

No current regulation in the Stick

1.

Make sure the machine is set-up

1. The Superimposition Board may

mode. Low open circuit voltage.

 

and configured correctly for the

be faulty

 

 

 

 

 

Stick mode,

 

 

 

 

 

 

 

2. The Output Module Transistor

 

 

 

 

Board may be faulty. See the

 

 

 

 

Secondary

Output

Board

 

 

 

 

Assembly

Test and

Wiring

 

 

 

 

Diagram.

 

 

 

 

 

 

There is no response to changes to

1.

Make sure the correct input volt-

1. The Control/Display board may

the output control settings. No cur-

 

age is applied to the machine.

be faulty.

 

 

rent regulation in all modes.

 

230 or 115VAC.

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

INVERTEC® V205-T AC/DC™

Page 47
Image 47
Lincoln Electric SVM161-A service manual Secondary Output Board Assembly Test