F-41

TROUBLESHOOTING AND REPAIR

F-41

 

SECONDARY OUTPUT BOARD ASSEMBLY TEST (continued)

FIGURE F.20 – SECONDARY POWER BOARD TEST POINT LOCATIONS

A

10K Ohms 10K Ohms

 

 

 

 

GA SA SB GB

I II I

3

B

2

1

TABLE F.13 – VOLTAGE CHECKS WITH 115 VAC APPLIED TO MACHINE

Generator/Mode

Test Point

Value

 

 

 

ON/STICK

GA[+],SA[-]

-13 VDC

 

 

 

ON/STICK

GB[+],SB[-]

+13 VDC

 

 

 

ON/STICK

3[+],1[-]

+ 0.5 VDC

 

 

 

ON/STICK

1[+]2[-]

+ 105 VDC

 

 

 

ON/STICK

OCV @ Outpt Terminals

+ 52 VDC

 

 

 

OFF/-

R GA-SA

10 K Ohms

 

 

 

OFF/-

R GB-SB

10 K Ohms

 

 

 