TROUBLESHOOTING & REPAIR |
FAULT CODES | DESCRIPTION/ |
| RESOLUTION |
| DEFINITION |
|
|
0081 | Average motor over cur- | • | The wire drive motor has overheated. |
| rent shutdown | • | Check to make sure the electrode |
|
|
| slides easily through the liner of the |
|
|
| gun. |
|
| • | Reduce the spindle brake resistance. |
|
| • | Reduce the amount of tension in the |
|
|
| wire drive tension arm. |
|
| • | For the best results, use only Lincoln |
|
|
| electrodes. |
|
| • | Wait 10 minutes for the wire feeder to |
|
|
| cool. |
0082 | Locked rotor condition | • | Verify that nothing is jammed in the |
| on the wire drive motor. |
| wire drive or gears. |
0086 | Trigger lockout. | • | The ripple of the power source OCV |
|
|
| is too high, greater than 110V. |
|
|
| (Across the Arc Models only) |
|
| • | Verify that the power source is |
|
|
| reconnected for the proper input |
|
|
| voltage. |
|
| • | Repair or replace the power source. |
|
|
| The power source does not conform |
|
|
| to NEMA. |
NOTE: If more than one fault message is being displayed, perform all the checks for the faults