F-9

TROUBLESHOOTING & REPAIR

F-9

FAULT CODES

DESCRIPTION/

 

RESOLUTION

 

DEFINITION

 

 

0081

Average motor over cur-

The wire drive motor has overheated.

 

rent shutdown

Check to make sure the electrode

 

 

 

slides easily through the liner of the

 

 

 

gun.

 

 

Reduce the spindle brake resistance.

 

 

Reduce the amount of tension in the

 

 

 

wire drive tension arm.

 

 

For the best results, use only Lincoln

 

 

 

electrodes.

 

 

Wait 10 minutes for the wire feeder to

 

 

 

cool.

0082

Locked rotor condition

Verify that nothing is jammed in the

 

on the wire drive motor.

 

wire drive or gears.

0086

Trigger lockout.

The ripple of the power source OCV

 

 

 

is too high, greater than 110V.

 

 

 

(Across the Arc Models only)

 

 

Verify that the power source is

 

 

 

reconnected for the proper input

 

 

 

voltage.

 

 

Repair or replace the power source.

 

 

 

The power source does not conform

 

 

 

to NEMA.

NOTE: If more than one fault message is being displayed, perform all the checks for the faults

before replacing the printed circuit board

LN-15