TOC
TOC
TROUBLESHOOTING AND REPAIR | ||
|
|
CONTACTOR REMOVAL AND REPLACEMENT PROCEDURE (Continued)
Return to Section
Return to Section TOC
Return to Section TOC
Return to Master
Return to Master TOC
Return to Master TOC
REPLACEMENT PROCEDURE
1.Install the new contactor using the four screws previously removed.
2.Replace the copper bus bar and cable.
3.Install the the contactor assembly into the case.
4.Using the 7/16” wrench mount the contactor assembly to the divider plate.
5.Install the two rubber mounts previously removed.
6.Connect the two coil leads.
7.Connect all group leads previously removed.
8.Using the 3/4” wrench replace the welding cable and lead 567 and 567A.
9.Replace the wire drive assembly.
10. Replace the roll cage.
Return to Section TOC
Return to Master TOC