Lincoln Electric SVM166-A service manual Figure F.14 Cover and Spindle Mount Location

Models: SVM166-A

1 93
Download 93 pages 60.43 Kb
Page 76
Image 76

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-38

TROUBLESHOOTING AND REPAIR

F-38

 

 

COVER AND SPINDLE MOUNT

REMOVAL AND REPLACEMENT PROCEDURE (Continued)

Figure F.14 - COVER AND SPINDLE MOUNT LOCATION

Cord Grip Nut

Spindle Mount

Cover

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

REMOVAL PROCEDURE

1.Remove input power to the LN-15.

2.Open door.

3.Locate the spindle mount and cover assembly. See Figure F.14.

4.Using the 1/2” wrench remove the one bolt from the top of the cover.

5.Using the 3/8” wrench remove the five mounting screws. See Figure F.15.

6.Using the large pliers loosen and remove the cord grip nut. See Figure F.14.

7.Pull the electrode cable inward through the rear case.

8.Disconnect the gas hose from the conductor block on the Wire Drive Assembly.

9.Carefully remove the cover and spindle assembly from the case. Be careful not to damage the switches, leads or solenoid.

10.If complete removal is necessary disconnect the leads from the switches and solenoid. Be sure to label for reassembly.

LN-15

Page 76
Image 76
Lincoln Electric SVM166-A service manual Figure F.14 Cover and Spindle Mount Location