TROUBLESHOOTING AND REPAIR

F-11

Troubleshooting Guide – See Wiring Diagrams for location of specified

Observe Safety Guidelines

components. See Wiring Diagrams for troubleshooting of specific circuits.

detailed in the beginning of this manual.

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

WIRE FEEDING AND WELDING PROBLEMS (Continued)

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

The wire feeds but starts and stops intermittently.

1.The gun trigger may be faulty. Check or replace.

2.Check for mechanical restrictions in the wire feed path.

1.The drive motor brushes may be faulty. Check and replace if less than 1/4 in. in length.

2.The wire feed speed potentiometer may be faulty. Check the resistance of the potentiometer over the entire range of travel. The potentio- meter should adjust from 0 to 10K Ohms. If adjustment is not smooth and linear, replace per Wire Feed Speed Potentio- meter Replacement procedure.

3.The Control PC Board may be faulty. Replace.

Return to Section TOC

Return to Master TOC

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

LN-7 GMA WIRE FEEDER

Page 75
Image 75
Lincoln Electric SVM 106-A service manual Wire Feeding and Welding Problems