ACCESSORIES

C-5

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

WIRE REEL DUST SHIELD FOR K376 50 TO 60 LB WIRE REEL MOUNTING STAND

A shield is available to cover the wire and reel to protect the wire from falling dirt and dust. Order part no. S-14543. Instructions are provided with the kit.

WIRE REEL DUST SHIELD DOOR FOR K303 AND K376

In extremely dusty and dirty locations this door kit can be added to those units having the dust shield kit (S-14543). This door kit includes a hinged door and sliding bottom seal. When these parts are attached to the reel support per the instructions included, the unit becomes a completely enclosed housing. Order part no. M11514.

K377 SMALL MOUNTING STAND FOR READ-REEL COILS OR 10 TO 30 LB SPOOLS WITH 2 IN. I.D.

This assembly includes a wire reel spindle (similar to the K162 spindle) attached to a small frame. The unit is supplied with the K363 Readi-Reel Adapter for using the Lincoln “Readi-Reel Electrode Coils”. Without the adapter the unit is capable of handling spools with a 2 in. I.D., a 12 in. maximum O.D., and a 4 in. width. For spools with an 8 in. O.D., a K468 spindle adapter is available. The spindle has an adjustable braking system. See Attaching the Wire Reel Stand procedure at the end of this section for installation procedures.

K378 SMALL MOUNTING STAND FOR 13 TO 14 LB INNERSHIELD COILS

This assembly includes the same smaller frame as used in the K377 and the fully

enclosed canister system for dereeling of the 14 lb coil. This system has a fixed brake for the 14 lb coil. See Attaching the Wire Reel Stand Procedure at the end of this section for installation procedures.

K292 POWER INPUT EXTENSION CABLE (600 AMPS)

Can be used to a maximum of 400 ft (122 m).

See Input Cable Connections section in the Installation Section for a description of this cable.

POWER INPUT CABLES

A variety of power input cable assemblies are available for various current ratings and power source connection types. All provide a polarized control cable plug (MS-3106A-18- 12S) and a lugged electrode cable for con- nection to the wire feeder.

K291 INPUT CABLE

The K291 input cable assembly consists of a six-conductor control cable and a 3/0 (85 mm2) electrode cable. It is rated at 600 amps, 60% duty cycle and is available in lengths of 10, 25, 50, 75, and 100 feet (3.0, 7.6, 15.2, 22.9, and 30.4 m).

K404 INPUT CABLE

The K404 input cable is similar to the K291 but includes a 1/0 (53 mm2) electrode cable. It is rated at 350 amps, 60% duty cycle. It is available in lengths of 10, 25, and 50 feet (3.0, 7.6, and 15.2 m). These control cables have lugged leads for power sources with stud output terminals and terminal strip control lead connections.

LN-7 GMA WIRE FEEDER

Page 51
Image 51
Lincoln Electric SVM 106-A Wire Reel Dust Shield Door for K303 and K376, K292 Power Input Extension Cable 600 Amps