TROUBLESHOOTING AND REPAIR

TRIGGER TRANSFORMER TEST

WARNING

Service and repair should only be performed by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353(WELD).

TEST DESCRIPTION

This test will determine if the correct voltages are being induced in the secondary windings of the trigger transformer.

MATERIALS NEEDED

115 VAC power supply Volt/Ohmmeter (Multimeter)

5/16 in. wrench or straight blade screwdriver Wiring Diagrams, Figure G.1 - G.3.

LN-7 GMA WIRE FEEDER

Page 78