Marantz Model VP-10S1 manual Troubleshooting, English, Symptom, Possible Cause, Remedy

Models: Model VP-10S1

1 47
Download 47 pages 24.82 Kb
Page 44
Image 44
TROUBLESHOOTING

ENGLISH

TROUBLESHOOTING

Try the following troubleshooting before calling for service.

1.Are the connections made properly ?

2.Are you operating the unit properly, following the instructions ?

If the unit does not operate properly, check the items shown in the following table.

If any trouble cannot be solved by the instructions below, malfunction of the internal circuitry is suspected; immediately unplug the AC power cord and contact Marantz dealer or service center.

Symptom

Possible Cause

Remedy

No power

AC power cord is not connected correctly.

Connect the AC power cord properly.

 

 

 

 

Lamp cover is not closed correctly.

Close the cover properly.

Image is not displayed.

A signal cable is not connected correctly.

Connect a signal cable properly.

 

 

 

 

Selected input is incorrect.

Select the correct input source .

 

 

 

 

The picture mute is active.

Press the MUTE button to release the mute.

Poor color.

Picture is not adjusted properly.

Adjust the picture in the MENU mode.

Picture is too dark.

Lamp life is running out.

Replace the lamp.

 

 

Contrast or brightness is not adjusted properly.

Adjust contrast or brightness properly.

 

Picture is not clear.

Picture is out of focus.

Adjust the focus.

 

 

Dew is on the lens.

Run the projector for about two hours.

 

Picture rolls.

A signal cable is not properly connected.

Connect a signal cable properly.

 

Batteries are exhausted.

Replace batteries.

 

 

 

 

The distance to the unit is too far.

Make the distance between the unit and the

The Remote Controller

remote control closer.

 

 

 

does not work.

IR sensor on unit is obstructed.

Remove any obstacles.

 

 

 

 

The “EXTERNAL” position on the connector

Select the “INTERNAL” position.

 

panel is selected.

 

 

 

 

 

Is the sensor cable disconnected?

Correctly connect the sensor cable.

Color temperature

 

 

Was the sensor correctly initialized?

Initialize the sensor by taking the correct

cannot be adjusted.

 

procedures.

 

 

 

 

Is the lens shift knob set to the correct

Set the lens shift knob to the correct (center)

 

(center) position?

position by taking the correct procedures.

 

 

 

Note:

If the lamp still does not function after the replacement and initialization of the lamp life, contact a Marantz authorized dealer, or service center.

Note: This projector uses a microcomputer. External noise can cause malfunctions. In such case, shut power OFF and unplug the power cable from AC power outlet. Then, plug the AC power cable back in, press the POWER button on the projector or the POWER ON button on the remote control and check operation.

42

Page 44
Image 44
Marantz Model VP-10S1 manual Troubleshooting, English, Symptom, Possible Cause, Remedy