Memory
calculations
153
Note 20 : The size of the protected multiple office code screening line
block is determined from the following:
2
words for each NXX code defined
2 words for each range defined (maximum_ 20 ranges perlocation code
-
80
words pds).
Note
21 : Templates are incremented in blocks of 10 words.
Note
22 : The trunk block size is 11.5 words with ODAS,
or 14.5 words in Releases 10 and
12,
or 19.5 words in Releases
13
and
15.
Note
23 : Requirements for voice/data port are the same as an SL-1 basic
telephone (Note 2) except the key layout portion of the template requires:
Before Release 9:
(24 + # of non-key features)/# of telephones sharing the same template-
After Release 9:
(10 + # of non-key features)/# of telephones sharing the same template.
Note
24 : Requirements for voice/data port are the same as an SL-1 basic
telephone (Note 2) except the key layout portion of the template requires:
Before Release 9:
(24 + # of non-key features)/# of telephones sharing the same template.
After Release 9:
(12 + # of non-key features)/# of telephones sharing the same template.
Memory calculations 553-2201-151 Appendix 1