74 Cabling
NT8D46AP Extended System’ Monitor Serial Link cable
Purpose-This cable is used to connect the System Monitor from one
column to another.
This cable is 7.6 m (25 ft) long.
NT8D46AQ System Monitor to UPS (Exide) cable
PurposeThis
cable is
used to connect the System Monitor to the Exide
UPS. It is used for UPS monitoring.
This cable is 13.7 m (45 ft) long.
NT8D46AS System Monitor inter-CPU cable
Purpose--This cable is used to connect
the dual CPUs in Meridian 1
System option 71 together for System Monitor monitoring. It replaces the
NT8D46AA System Monitor column cable in both CPU modules.
NT8D46AT System Monitor to QBLIS cable
Purpose-This cable
connects the System Monitor to the
QBLl5
power/battery distribution box. It is used to monitor the DC power plant.
This cable is 9.7 m (32 ft) long.
.-
NT8D46AU System Monitor to UPS (Alpha) cable
Purpose-This
cable is used to connect the System Monitor to the Alpha
UPS. It is used for UPS monitoring.
This cable is 13.7 m (45 ft) long.
NT8D46AV System Monitor to QCA13 cable
Purpos-This
cable
connects the System Monitor to the QCA13 DC
power plant. It is used to monitor the DC power plant.
This cable is 9.7 m (32 ft) long.
Equipment identification and ordering information 553-3001-154