PRACTICE 553-2201-182
Table 2-G
-
ENVELOPE DELAY DISTORTION
BANDWIDTH
(Hz)
ENVELOPE DELAY DISTORTION
(,us)
LINE-LINE LINE-TRUNK/
TRUNK-LINE/
TRUNK-TRUNK
1000
to 2600
380 190
1150
to 2300
300 150
800 to 2700 750
375
Note:
The limits above apply to 95% of all connections.
Table 2-H
CROSSTALK
CONNECTION CROSSTALK
AlTENUATlON
(dB)
Line-to-Line
>75
Line-to-Trunk
>75
Trunk-to-Trunk
>75
Note: Frequency range of test signal 0.2 to 3.4
kHz
at
-10
dBm. __
Table 2-J
OVERLOAD LEVELS
TYPE NOMINAL OVERLOAD LEVEL
(dBm)
CIROC’UIT
TRANSMIT
RECEIVE
Line
Trunk
::
il
;
‘.
7
y/ :.
;
.:-.
,.;
-/
Page 2-5
.
.