SecurStor 16i Installation and Hardware Reference Manual

Figure 2-2: Loosening the BBU Retention Screws

Step 3. Once the retention screws are loosened, gently retrieve the dummy plate out of the enclosure. (See Figure 2-3)

Figure 2-3: Removing the BBU Slot Dummy Plate

NOTE:

It may be difficult to remove the dummy plate as it is embedded in the subsystem chassis. If you are unable to dislodge the sheet, wedge the head of a flat-head screwdriver between the metal sheet and the chassis and then gently nudge the metal sheet out of the chassis.

Step 4. Install the BBU module. Align the BBU module with the BBU module slot and gently insert the BBU module until the back of the BBU module reaches the end of the slot. Use slightly more force so that the back-end connector can mate with the backplane.

Step 5. Secure the BBU module to the chassis. Fasten the two (2) retention screws on the BBU module to secure the BBU module to the chassis. (See Figure 2-4)

2-6

Page 32
Image 32
Meridian Data 16i manual Loosening the BBU Retention Screws