Chapter 3 Subsystem Monitoring

 

Upper Threshold

Lower Threshold

+3.3V

+3.6V

+2.9V

+5V

+5.5V

+4.5V

+12V

+13.2V

+10.8V

CPU Temperature

90ºC

5ºC

Controller Board

80ºC

5ºC

Temperature

 

 

Enclosure Ambient

40ºC

0ºC

Temperature

 

 

Table 3-7: Default Threshold Values

3.3.2 Failed Devices

If any of the following components fails, the audible alarm will be triggered:

RAID controller module

Cooling fan modules

PSU modules

BBU module

Hard disk drives

NOTE:

When temperature exceeds a preset threshold, the controller’s charger circuits will stop charging. You will then receive a message that says “Thermal Shutdown/Enter Sleep Mode.” When the temperature falls back within normal range, the battery will resume charging.

3.4 I2C Monitoring

Formatted: Bullets and Numbering

Deleted:

The operating status of PSU and cooling fan modules are collected through an I2C serial bus. If either of these modules fails, the failure will be detected and you will be notified through the various methods described above.