SCSI Interface126

Installation

Attention
It’s very important to protect the printer controller board and any
associated circuit boards from electrostatic damage . Before performing
this procedure, review the antistatic caution on page 105. In addition,
always handle circuit boards by the edges only.
1Turn off the printer, and then disconnect
the power cord and all interface cables
from the printer.
2Loosen five screws and, using the tab on
the lower side of the panel, pull the
controller board from the printer.
3Remove the two screws holding the metal
plate over the SCSI interface opening.
4You can dispose of the metal plate and
screws according to local regulations.
5Attach the SCSI
interface card to
the controller
board.
aPosition the
SCSI interface
card so that its
ribbon cable
connector
aligns with the
SCSI connec-
tor on the con-
troller board.
bGently press
the ribbon cable
connector down until it’s fully seated.
Attention
Make sure that the connectors on the ribbon cable and the controller
board are properly aligned. Damage to the controller board could
result if the pins are misaligned.
cInsert the SCSI interface card connector into its opening in the
interface panel.
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIII
................................................ ........................ ..........
................................................ ........................ ..........
................................................ ........................ ..........
................................................ ........................ ..........
..................
...................
..................
...................