Moxa Technologies 5400 Series user manual Reverse Telnet Mode

Models: 5400 Series

1 104
Download 104 pages 34.06 Kb
Page 51
Image 51
Reverse Telnet Mode

NPort 5400 Series User’s Manual

Web Console Configuration

Reverse Telnet Mode

TCP alive check time

Setting

Factory Default

Necessity

0 to 99 min

0

Optional

Specifies the time slice for checking if the TCP connection is alive. If no response, the NPort 5400 will disconnect the original connection.

Inactivity time

Setting

Factory Default

Necessity

0 to 65535 ms

0

Optional

 

 

 

Idle time setting for auto-disconnection. 0 min.

means it will never disconnect.

 

Local TCP port

 

 

Setting

Factory Default

Necessity

1 to 65535

4001

Optional

 

 

 

Each of the NPort’s serial ports is mapped to a TCP port. To avoid conflicts with TCP ports, set port numbers to 4001 for port1, 4002 for port 2, etc. (like the default values).

Map <CR-LF>

Setting

Factory Default

Necessity

CR, LF, or CR-LF

CR-LF

Optional

 

 

 

If data received through the NPort 5400’s Ethernet port is sent using the “enter” command, the data will be transmitted out the serial port with an added

(1)“carriage return + line feed” if you select the <CR-LF> option

(i.e., the cursor will jump to the next line, and return to the first character of the line)

(2)“carriage return” if you select the <CR> option

(i.e., the cursor will return to the first character of the line)

(3)“line feed” if you select the <LF> option.

(i.e., the cursor will jump to the next line, but not move horizontally)

5-25

Page 51
Image 51
Moxa Technologies 5400 Series user manual Reverse Telnet Mode, Idle time setting for auto-disconnection. 0 min