Moxa Technologies 5400 Series Serial Parameters, Port alias, Baud rate, Data bits, Stop bits

Models: 5400 Series

1 104
Download 104 pages 34.06 Kb
Page 36
Image 36
Port alias

NPort 5400 Series User’s Manual

Web Console Configuration

 

Port alias

 

 

 

 

Setting

Factory Default

Necessity

 

 

1 to 15 characters

None

Optional

 

 

(E.g., PLC-No.1)

 

 

 

Port Alias is specially designed to allow easy identification of the serial devices which are connected to the NPort’s serial port.

Serial Parameters

ATTENTION

Check the serial communication parameters in your Serial Device’s user’s manual. You should set up the NPort’s serial parameters with the same communication parameters used by your serial devices.

Baud rate

Setting

Factory Default

Necessity

50 bps to 921600 bps

115200 bps

Required

 

 

 

The NPort supports baud rate setting from 50

bps to 921.6 Kbps.

 

Data bits

 

 

Setting

Factory Default

Necessity

5, 6, 7, 8

8

Required

 

 

 

When the user sets Data bits to 5 bits, the stop bits setting will automatically change to 1.5 bits.

Stop bits

Setting

Factory Default

Necessity

1, 2

1

Required

 

 

 

Stop bits will be set to 1.5 when Data bits is

set to 5 bits.

 

Parity

 

 

Setting

Factory Default

Necessity

None, Even, Odd, Space, Mark

None

Required

Flow control

 

 

Setting

Factory Default

Necessity

None, RTS/CTS, DTR/DSR, Xon/Xoff

RTS/CTS

Required

 

 

 

FIFO

 

 

Setting

Factory Default

Necessity

Enable, Disable

Enable

Required

 

 

 

The NPort’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. Disable the FIFO setting when your serial device does not have a FIFO to prevent data loss during communication.