Multiquip LS600P operation manual inspection, Adding Hydraulic Oil Filler Hole, Top Cover

Models: LS600P

1 88
Download 88 pages 1.68 Kb
Page 31
Image 31
Figure 14. Adding Hydraulic Oil (Filler Hole)

inspection

2.If the hydraulic oil level is low, remove the hydraulic oil tank cap just above the oil level sight glass (Figure 14) and add the correct amount of hydraulic oil to bring the hydraulic oil level to a normal safe operating level. Use Shell oil Tellus 68 or Mobil oil DFE26.

CAP

FILLER

HOLE

Figure 14. Adding Hydraulic Oil (Filler Hole)

3.Check the oil level in the lubrication box (Figure 15). If low, fill with up to 3 gallons of SAE #30 motor oil (Figure 14). The oil level must be checked daily. The lubrication box should be serviced as described in the maintenance section.

TOP

COVER

TION

LUBRICABOX

Figure 15. Filling the Lubrication Box