operation
Radio Remote Control Programming
Before starting operation of the
Screen 9
RADIO ADDRESS 9
NO RADIO
PRESS RESET TO
LEARN A NEW ONE
1.Press the ON/OFF button on the radio (wireless) remote control to turn on the power. Hold down the RESET switch. The display will now show.
Screen 9
RADIO ADDRESS 9
NOW SCANNING
FOR NEW
TRANSMITTER
2.After 5 seconds, the display will show:
Screen 9
RADIO ADDRESS 9
COMMUNICATING
PRESS RESET TO
LEARN A NEW ONE
3.The
Remote Control Cable Operation (25 ft.)
The remote control cable (Figure 40) has the following controls:
Pump ON/OFF – Starts and stops the forward pumping. Pump REV – Starts pumping in reverse direction.
Connect the remote control cable (Figure 40) to the receptacle labeled remote located on front of the digital panel.
REMOTE CONTROL CABLE UNIT
25 FT. CABLE
PUMP REV
PUMP ON/OFFTO CONTROL BOX CONNECTOR
Figure 40. Remote Control Cable
Before the remote control cable can be used the pumping volume rate must be set.
1.Start the pump as outlined in the pumping section of this manual.
2.Place the pumping control switch in the LOCAL position.
3.Using the momentary volume control switch, adjust the pumping rate (volume) to the desired strokes per minute.
4.Once the desired pumping rate has been acheived, place the pumping control switch in the REMOTE position.
page 38 — MAYCO LS600P CONCRETE PUMP • operation manual — rev. #0 (05/13/13)