Multiquip MQP60IV, MQP20IZ Mechanical Installation — Battery System, Engine Starting System

Models: MQP60GM MQP30DZ MQP30GM MQP50IZ MQP60IV MQP45GM MQP40IZ MQP20IZ

1 94
Download 94 pages 19.21 Kb
Page 51
Image 51
MECHANICAL INSTALLATION — BATTERY SYSTEM

MECHANICAL INSTALLATION — BATTERY SYSTEM

Engine Starting System

Battery Starting Systems

Battery starting systems for generator sets are 12 volt or 24 volt DC (Figure 16). When installing a battery system to start a generator set, consider the following:

„See the Battery Safety Instructions on page 11.

„Batteries must have enough capacity to provide the cranking motor current indicated on the genset specification sheet. The batteries may be either lead- acid or nickel-cadmium. Refer to the dealer for approved battery brand names.

„A high output engine-driven alternator and automatic voltage regulator are provided with the genset to recharge the batteries during operation.

„For most emergency power systems, a float-type battery charger, powered by the normal power source (commercial power), must be provided to keep the batteries fully charged during standby. See the battery charger section for more information.

„Local codes or site conditions may require battery heaters to maintain a minimum battery temperature of 50°F (10°C) if the battery is subject to freezing temperatures.

„Standard gensets include battery racks and battery cables.

„Battery cable resistance must not result in a voltage drop between the battery and the starter motor of more than 1 volt for 12 volt systems or more than 2 volts for 24 volt systems.

Figure 16. Typical Lead Acid Type Battery

Electrolyte is an acid and must be handled with caution. Servicing instruction from the electrolyte manufacturer must ALWAYS be followed to ensure safety. Serious injury can result from careless handling and non-compliance to safety handling instructions.

Overfilling the battery may cause the electrolyte to overflow resulting in corrosion to nearby components. Immediately wash off any spilled electrolyte (battery acid). Additionally, when connecting the positive (+) cable to the battery's positive (+) terminal post, DO NOT allow contact of the wrench or any metallic object to come in contact with the battery's negative (-) terminal post. This may result in an electrical short circuit or an explosion.

INDUSTRIAL GENERATOR SETS — APPLICATION & INSTALLATION MANUAL — REV. #4 (09/07/07) — PAGE 51

Page 51
Image 51
Multiquip MQP60IV, MQP20IZ Mechanical Installation — Battery System, Engine Starting System, Battery Starting Systems