OFFICE DATA DESIGN

Procedure for Setting Office Data for OAI Services

3.3.3Data Programming

Assignment

1.ASYD (System Data)

SYS1 INDEX 77

b2: 0 (MW Lamp Refresh Control is in service) INDEX 179

b6: 0 (OAI services are provided)

2.ARPC (Remote Point Code for Centralized Service)

For providing centralized services at the Message Center within a No. 7 CCIS Network, assign the point codes for the remote offices belonging to the main office

CSN: Centralized Service Item No. (1 ~ 7) 1: Message Center

CNT: Number of Remote Office Point Codes (1 ~ 32)

RPC: Remote Office Point Code (1 ~ 16367)

Deletion

1. ARPC (Remote Point Code for Centralized Service)

Delete the point codes of the remote offices belonging to the main office

2.ASYD (System Data)

SYS1 INDEX 77

b2: 1 (MW Lamp Refresh Control is not in service) INDEX 179

b6: 1 (OAI services are not provided)

ND-70895 (E)CHAPTER 5

Page 71

Revision 1.0

Page 81
Image 81
NEC ND-70895 (E) system manual SYS1 Index