OFFICE DATA DESIGN

Procedure for Setting Office Data for OAI Services

3.1.2Using Conditions

1.Normal and abnormal operating sequences pertaining to the basic connection of the SCF are as described below.

[Normal Sequence]

 

 

 

Destination Terminal

Calling Terminal

NEAX2400

Computer (AP)

 

 

 

SCF Activated

 

 

Terminal Check

 

 

 

Return Result

 

 

Connection

 

<Zip tone>

<Zip tone>

 

 

(a)Upon receiving SCF start request from the AP, the NEAX2400 IMX judges the status (idle, busy, makebusy, etc.) of the designated calling terminal and destination terminal.

(b)If the calling terminal and the destination terminal are idle, the NEAX2400 IMX sends out Return Result to the AP, and places the calling terminal into an outgoing connection status and the destination terminal into ringing status.

These are the basic functions.

(c)When the destination terminal designated from the AP is a terminal in the NEAX2400 IMX and automatic answer is designated as the answer type, both the calling and destination terminals can be placed into speech status immediately from the status cited in (b) (After zip tone has been sent to both terminals, the terminals are placed into speech status.).

Note that this service function is valid only when the destination terminal is in line selection wait status and also automatic answer is designated as the answer type. In other words, if the destination terminal is in a status other than line selection wait status, the call is to be answered

manually. Further, this service function is valid only when the destination terminal is a station (Dterm: Voice) among the SCF Make Call designations. In other words, if the call destination

is a trunk, this service function does not work.