OFFICE DATA DESIGN

Procedure for Setting Office Data for OAI Services

(d)The node that accommodates the IP must be initialized when all the other nodes are in on-line mode.

(e)The User’s Application (UAP) must be booted up after the confirmation of the establishment of the Fusion link.

(f)When you add a node/nodes to the network, you have to initialize the node that accommodates the IP.

3.7.1.3Data Programming

STEP 1: Assignment of System Data

(Data for OAI Fusion)

ASYDL/ASYDN

The data below must be set to all nodes in the network

(a)ASYDL-SYS1 INDEX512 b0~7: Assign the self-Fusion Point Code (self-FPC) at each node.

(1~253)

INDEX865 b0~7: FPC of the node providing IP

Note: Assign 0 for the node that providing IP in the self-node only.

(b) ASYDN-SYS1 INDEX514

: NDM usage

INDEX533

: FPC number of the node that has the standard VNDM

 

(1-253)

STEP 2: Data programming procedures other than STEP 1 are the same as that of the non-Fusion system. Therefore, only notification or condition of the data programming is shown below in this section.

(a)ASYD/ASYDL

The data below are set to the node that accommodates IP ASYD - SYS1, INDEX207, b0:1=IP0 is used

SYS1, INDEX207, b1:0/1=IP1 is not used/used ASYDL - SYS1, INDEX864, b0:1=Built-in IP is used

The others are set to all nodes in the Fusion network.

(b)Following are the notification Fusion data programming with commands below.

For the following commands, assign data by the corresponding commands written in NDM.

AMNON (AMNON is used in place of AMNO)

ACNON (ACNON is used in place of ACNO)

AADTN (AADTN is used in place of AADT)

(c)The AKYD, AOKC command data are set to all nodes in Fusion network to be provided OAI system. (For these commands, assign data by the corresponding commands written in DM)

CHAPTER 5

ND-70895 (E)

Page 80

Revision 1.0

Page 90
Image 90
NEC ND-70895 (E) system manual Assignment of System Data Data for OAI Fusion, Asydl/Asydn, INDEX533, 253