OFFICE DATA DESIGN

Procedure for Setting Office Data for OAI Services

1.The following are the quick reference table of optional software and system data programming for each OAI system configuration. (See Figure 5-1“Network Configuration of OAI systems” for network configuration of OAI systems.)

Table 5-1 OAI Software and System Data

 

 

Type and Node

I

II

 

III

OAI

 

 

 

 

 

 

 

 

 

PBX1

PBX2

PBX3

 

PBX4

 

 

 

 

 

 

 

OAI Software

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

OAI Option Service software (basic)

 

 

 

 

 

 

[Series 7400 (Release 8)]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

ACD Option Service Software for “Agent Anywhere”

 

 

 

 

 

 

 

 

 

 

 

 

 

System Data

 

 

 

 

 

 

3

CM Usage

Note 1

0

4

4

 

4

(ASYD:SYS1, INDEX31, b0~b3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

OAI in service/out of service

 

1

0

0

 

0

(ASYD:SYS1, INDEX79, b6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

No.0 CPU Mounted Status of IP00/1: Not mounted/Mounted

0

1

0

 

1

(ASYD:SYS1, INDEX207, b0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

No.1 CPU Mounted Status of IP00/1: Not mounted/Mounted

0

Note 2

0

 

Note 2

(ASYD:SYS1, INDEX207, b1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

OAI Call Processing Event Notification

 

0

1

1

 

1

(ASYD:SYS1, INDEX241, b2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

SCF Return Error Detail Notification

 

0

1

1

 

1

(ASYD:SYS1, INDEX241, b3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Built-in IP:Not used/Used

 

0

1

0

 

1

(ASYDL:SYS1, INDEX864, b0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

OAI Terminal Anywhere:Out of service/In service

Note 3

0

0

1

 

1

(ASYDL:SYS1, INDEX864, b2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

MULTIPLE IPs:Out of service/In service

Note 4

0

0

1

 

1

(ASYDL:SYS1, INDEX864, b3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

FPC Number of the node providing IP

 

0

0

Note 5

 

Note 5

(ASYDL:SYS1, INDEX865)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

Number of ports for SMFN (terminal)

 

0

Note 6

Note 6

 

Note 6

(ASYDL:SYS1, INDEX864, b4~5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

FPC Number of Center Node providing VNDM (ASYDN:SYS1,

Note 7

Note 7

Note 7

 

Note 7

INDEX533)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

The software is installed to be linked with the standard service software using MSVIP command.

 

 

 

Note 1: When CM is used for another function, this setting may be changed. (Ex. Assign “6” Hex. when FLF Fusion service is used.)

Note 2: When the CPU in system 1 is used, assign “1”.

Note 3: Assign “1” at the all nodes using “OAI Terminal Anywhere” in the Fusion network that “MULTIPLE IPs” is provided.

Note 4: When the all fusion nodes in the network are used for “MULTIPLE IPs”, this data may be assigned using ASYDN.

Note 5: This data is required for UAP connection.

Note 6: (This data is not necessary for the example above.) Assign this data so that the proper number of ports can be used when more than three ports of Status Monitoring for terminal (SMFN). The identical data should be assigned at all nodes.

ASYDL SYS1 INDEX864 b4~5:

b5

 

b4

 

0

0

=2 ports

0

1

=8 ports

Note 7: When the node using “OAI Terminal Anywhere” is included in the Fusion network that “Multiple IPs” is provided, assign the FPC no. of IP node using “OAI Terminal Anywhere”.

ND-70895 (E)CHAPTER 5

Page 83

Revision 1.0