INSTALLATION PROCEDURE
Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX
4. Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX
The procedure for upgrading OAI System NEAX2400 ICS to NEAX2400 IMX is shown below.
4.1 Up Grading Procedure
STEP 1: Stop the operation of the external computer by the appropriate procedure.
STEP 2: Upgrade the PBX hardware following by the Upgrade Manual for the PBX.
STEP 3: Upgrade the PBX software to install the software below.
•Assortment of software for NEAX2400 IMX Note 1
•OAI Optional software
STEP 4: Program the following OAI commands data again.
• ASYDL Note 2
STEP 5: Start Up the external computer Note 3
•hardware and software of the external computer STEP 6: Perform the installation test.
Note 1: This software is commonly used with all types of systems. Data Memory does not have to be changed.
Note 2: For detail, see Section 3. “OAI Software Installation”.
Note 3: This procedure is not necessary for the ACD system without MIS. For more information, see Section 2. “Cable Connections with External Computer”. The TCP Port number of the external computer has to be changed to “60030” for NEAX2400 IMX.
Page 23
Revision 1.0