MAINTENANCE

System Messages

3.2.2Message Detail Data of System Message “26-V”

System Message 26-V: LAN Interface Error Report (OAI/MIS) 1. Print-out Format

SYSTEM MESSAGE 26-VLAN INTERFACE ERROR REPORT

NEC - ESDJULY 25 19:30

TCP/IP PartApplication Part

1: xx xx xx xx xx xx xx xx

1

2

3

4

5

6

7

8

2: xx

xx

xx

00

00

00

00

00

9

10

11

12

13

14

15

16

2. Print-out information (typical)

-TCP/IP part-

 

 

1

~

4

IP address of the error-detected OAI/MIS terminal

5

~

6

Port No.

7

 

 

Used socket No.

8

 

 

Error Code (TCP/IP part)

-Application Part-

9

 

 

Application Type

 

 

 

05

= OAI

 

 

 

07

= MIS (ACD)

10

 

 

Faulty Logical Port No.

11

 

 

Error Kind (ERRK)

 

 

 

01

= SEND Execution Error

 

 

 

02

= RECEIVE Execution Error

 

 

 

03

= TCP/IP Connection Error

 

 

 

04

= Connection Error (B-level Infinite Loop, etc.)

 

 

 

05

= TCP/IP Port Capacity Over

ND-70895 (E)CHAPTER 6

Page 91

Revision 1.0

Page 101
Image 101
NEC ND-70895 (E) system manual System Message 26-VLAN Interface Error Report, = Oai, = Mis Acd