NDA-24305 CHAPTER 6
Page 293
Revision 1.0
Q-SIG (CIRCUIT SWITCHED BASIC CALL - ETSI VERSION)
Note 3: Assign “1” when the number display on LCD of terminal is required.
Note 4: Assign “1” when the User-to-User Signaling notification is required.
Note 5: Assign “1” when the multi-rate bearer service is used.
STEP 4: ARTI - Assign the trunk application data for Bch and Dch as follows.
INTD=0 (Q-SIG)
Note: This data is effective since re lease 4.
STEP 5: ATRK - Assign Bch trunk data. Note that Dch trunk data should be assigned after STEP 9: ACIC 2
command assignment.
STEP 6: ADPC - Assign PC (Point Code) for both Bch and Dch at each physical interface.
Note: Same PC (not existing PC for CCIS) must be assigned for both Bch and Dch. The Point Code does not
have any relationship to the other PBX’s like in CCIS
STEP 7: ACSC - Assign the location of DCH (Dch Handler).
(Refer to the following example)
STEP 8: ACIC 1 - Assign CSCG
PC=xxx CSCG=Even No. (130-254)
STEP 9: ACIC 2 - Assign CIC No.
PC=xxx CIC (1~999) LENS (for speech channel)
STEP 10: ATRK - Assign the LEN of Dch trunk.
Note: The following data is available if necessary.
ASFC - SFI 139 : SID to Network - Privacy [COLR] for Q-SIG.
0 =
1 = SID to Network - Privacy
PIM0
Group
No.
05 07
04 06
CSCG=130 (Even No.) CICG No. = 0 CCH= 0004
1 0004
2 0004
3 0004
4 0004
5 0004
6 0004
7 0004
PRT
Note: Bch location is not necessary. (DCH location only)
Attention: The circuit card
must
be initialized after changing data.