Alteon OS Command Reference

/cfg/l2/thash

IP Trunk Hash Configuration

[IP Trunk Hash Menu]

set

-

IP Trunk Hash Settings Menu

cur

-

Display current IP trunk hash configuration

Use the following commands to configure IP trunk hash settings for the GbESM.

Table 6-43IP Trunk Hash Menu Options (/cfg/l2/thash)

Command Syntax and Usage

set

Displays the Trunk Hash Settings menu. To view menu options, see page 236.

cur

Display current trunk hash configuration.

/cfg/l2/thash/set

IP Trunk Hash

[set IP Trunk

Hash Settings Menu]

smac

- Enable/disable smac hash

dmac

- Enable/disable dmac hash

sip

- Enable/disable sip hash

dip

- Enable/disable dip hash

cur

- Display current trunk hash setting

Trunk hash parameters are set globally for the GbE Switch Module. You can enable one or two parameters, to configure any of the following valid combinations:

„SMAC (source MAC only)

„DMAC (destination MAC only)

„SIP (source IP only)

„DIP (destination IP only)

„SIP + DIP (source IP and destination IP)

„SMAC + DMAC (source MAC and destination MAC)

236 „ The Configuration Menu

43W7774, May 2007

Page 236
Image 236
Nortel Networks 43W7774 IP Trunk Hash Configuration, Cfg/l2/thash/set, 43IP Trunk Hash Menu Options /cfg/l2/thash