Alteon OS Command Reference

/info/sys/general

General System Information

System Information at 0:16:42 Wed Jan 3, 2007

Time zone: No timezone configured

Nortel 10Gb Uplink Ethernet Switch Module

Switch is up 5 days, 2 hours, 16 minutes and 42 seconds.

Last boot: 0:00:47 Wed Jan 3, 2007 (power cycle)

MAC address: 00:11:58:ad:a3:00 Management IP Address (if 128): 10.90.90.97

Software Version 1.1.0 (FLASH image1), factory default configura- tion.

PCBA Part Number:

 

317857-A

 

 

FAB Number:

 

EL4512011

 

 

Serial Number:

 

YJ1WDW47N277

 

Manufacturing Date:

 

0

 

 

Hardware Revision:

 

 

 

Board Revision:

 

0

 

 

PLD Firmware Version:

5.0

 

 

Temperature Sensor

1

(Warning):

42.5

C (Warn at 85.0 C/

Recover at 79.0 C)

2

(Shutdown):

44.0

C (Warn at 93.0 C/

Temperature Sensor

Recover at 86.0 C)

3

(Exhaust):

42.5

C

Temperature Sensor

Temperature Sensor

4

(Inlet):

42.5

C

Switch is in I/O Module Bay 0

NOTE The display of temperature will come up only if the temperature of any of the sensors exceeds the temperature threshold. There will be a warning from the software if any of the sen- sors exceeds this temperature threshold. The switch will shut down if the power supply over- heats.

System information includes:

„System date and time

„Switch model

„Switch name and location

„Time of last boot

„MAC address of the switch management processor

70 „ The Information Menu

43W7774, May 2007

Page 70
Image 70
Nortel Networks 43W7774 manual Info/sys/general, General System Information