Alteon OS Command Reference

Table 6-40GVRP Menu Options (/cfg/l2/gvrp)

Command Syntax and Usage

off

Globally turns GVRP off. With GVRP off, the switch does not process GPDUs.

When you turn GVRP off, existing dynamic VLANs are deleted.

cur

Display current GVRP configuration.

/cfg/l2/gvrp/port

GVRP Port Configuration

[GVRP Port EXT2

Menu]

setreg

-

Set learning GPDU for registrar of this port

setapp

-

Set sending GPDU from applicant of this port

ena

-

Enable GVRP support for this port

dis

-

Disable GVRP support for this port

cur

-

Display current GVRP port parameters

Use the following commands to configure GVRP settings for the port.

Table 6-41GVRP Port Menu Options (/cfg/l2/gvrp/port x)

Command Syntax and Usage

setreg normalblock

Configures GPDU learning for the port’s GVRP registrar, as follows:

„Normal: The registrar listens for GPDUs, and learns GVRP attributes from other devices on the network.

„Block: The registrar does not listen for GPDUs from other devices.

setapp normalblock

Configures GPDU sending for the port’s GVRP applicant, as follows:

„Normal: The applicant sends GPDUs to other devices on the network.

„Block: The applicant does not send GPDUs to other devices.

ena

Enables GVRP on the port.

dis

Disables GVRP on the port.

cur

Display current GVRP port configuration.

234 „ The Configuration Menu

43W7774, May 2007

Page 234
Image 234
Nortel Networks 43W7774 manual Cfg/l2/gvrp/port, Gvrp Port Configuration, 41GVRP Port Menu Options /cfg/l2/gvrp/port