Installing the server and connecting the peripheral devices

Standard 1.0

2Connect the other end of the DC power cable to the Power Distribution Unit (PDU). See details below:

The following photograph shows the keyed plug of the DC power cable. This plug connects to the PDU:

Note: If you are not using a Nortel Networks-supplied PDU, snip this plug and connect the cable appropriately to your DC power plant. Remember that a red cable is positive, a black cable is negative, and a green cable is the ground.

3Turn on the PDU.

To start the server

1Press the server’s power switch to start the server.

2Observe the Power-On Self-Test (POST) and initialization messages on the monitor.

3When the following menu appears on the monitor, select option 1 to boot Windows NT:

Select one of the following:

---------------------------

1 Windows NT 4.0 Server (Default within 30 secs)

2 Windows NT 4.0 Server (VGA mode) Choose an option[1,2]?1

The Windows NT startup sequence begins.

4Ensure that the Windows NT logon window appears on the monitor.

Note: If the Windows NT logon window does not appear, refer to Part 5 of the CallPilot Installation and Configuration binder for troubleshooting instructions.