North Star 864 HH Gas Line Requirements, Fuel, Gas Line Connection, Gas Inlet Pressure, 4070201

Models: 864 HH

1 68
Download 68 pages 62.14 Kb
Page 17
Image 17
Gas Line Requirements

Installation (for qualified installers only)

17

Gas Line Requirements

MASSACHUSETTS INSTALLATIONS - WARNING:

THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS.

OTHER MASSACHUSETTS CODE REQUIREMENTS:

Flexible connector must not be longer than 36 inches.

Shutoff valve must be a “T” handle gas cock.

Only direct vent sealed combustion products are approved for bedrooms or bathrooms.

Fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas log.

A carbon monoxide (CO) detector is required in the same room as the appliance.

The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1 and the requirements listed below.

The fireplace and gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig. For pressures under 1/2 psig, isolate the gas supply piping by closing the manual shutoff valve.

Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.

Fuel

This fireplace is designed either for natural gas or for propane (but not for both). Check the sticker on the top of the gas control valve to make sure the correct fuel is used.

Gas Line Connection

Installation must be performed by a qualified installer, service agency or the gas supplier (In Massachusetts a licensed plumber/gasfitter).

Gas Inlet Pressure

Standard Input Pressure

Minimum Input Pressure

Maximum Input Pressure

 

 

 

 

 

 

 

Natural Gas

7" W.C. (1.74 kPA)

3.5" W.C. (0.87 kPA)

13.85" W.C. (3.45 kPA)

Propane

13" W.C. (2.73 kPA)

8" W.C. (1.99 kPA)

14" W.C. (3.48 kPA)

If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.

The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure.

© Travis Industries

4070201

100-01182_002

Page 17
Image 17
North Star 864 HH installation manual Gas Line Requirements, Fuel, Gas Line Connection, Gas Inlet Pressure, 4070201