Vent with No 45° Elbow

26

Installation (for qualified installers only)

Rear Vent Configuration with Horizontal Termination (no vertical rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and diffuser positions.

HINT: Travis Industries provides a minimum rear vent kit (sku 98900168). It includes a 4” section and a horiztontal termination cap.

Vent with No 45° Elbow

3 feet

0 feet

0feet

(max)

 

4'

Exhaust Restrictor Removed

Intake Restrictor # 1 (stock)

Diffuser Position # 1 (stock)

Min. 4" Horizontal Section

Max.48" Horizontal Section(s)

Vent with 1 45° Elbow

3 feet

0 feet

0feet

(max)

 

2'

See the charts above to determine maximum vent

Optional 45° Elbow

Termination

Exhaust Restrictor Removed

Intake Restrictor # 1 (stock)

Diffuser Position # 1 (stock)

Min. 4" Horizontal Section

Max. 24" Horizontal Section(s)

EXHAUST RESTRICTOR REMOVAL

 

Firebox

 

Roof

Back

 

 

Wall

of

Firebox

 

If venting to the rear with no vertical rise, remove and discard the exhaust restrictor. Replace the screws in the same holes.