North Star Wiring Instructions, Wiring Diagram - 864 HH*, 44 DV XXL, and 36 DV, 4070201

Models: 864 HH

1 68
Download 68 pages 62.14 Kb
Page 62
Image 62
Wiring Instructions

62

Optional Equipment (for qualified installers only)

Wiring Instructions

Warning: All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the current National Electric Code ANSI/NFPA 70.

Warning: Make sure the fireplace electrical circuit is disabled prior to working on electrical hookup.

Wiring Diagram - 864 HH*, 44 DV XXL, and 36 DV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fireplace

 

 

 

 

 

 

Blower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Snap Disk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

 

 

Hot

 

 

 

 

 

 

 

 

 

Hot

 

 

 

 

 

Molex

 

 

 

 

Molex

 

 

 

 

Hot

 

 

 

 

 

Common

 

 

 

 

 

 

 

 

Common

 

 

 

 

 

 

 

 

 

 

 

 

 

Common

 

 

 

 

 

 

(black)

 

 

 

 

 

 

 

 

(black)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(black)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector

 

 

 

Connector

 

 

 

 

 

 

 

Power

 

 

(white)

 

 

 

 

 

 

(white)

 

 

 

 

 

 

 

(white)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

 

 

 

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

 

 

 

 

(green)

 

 

 

 

 

 

(green)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(green)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot

(black)

Common

(white)

Ground (green)

Hot

(black)

Heat Duct Rheostat

Rheostat

Junction

Box

Hot

(black)

Common

(white)

Ground (green)

Heat Duct

Blower

Hot

(black)

Common

(white)

Ground (green)

Blower

Junction

Box

Grounded

 

to Blower

Fireplace Fireplace

Blower Rheostat

Common

(white)

Ground (green)

Optional Second Heat

Duct (same rheostat and

blower wiring as above)

Wiring Diagram -864TRV

*864 HH SN 3407-001010 or greater. 864 HH SN 3407-001009 or less uses wiring similar to the 864TRV.

Power SupplyWiring Diagram - 864 HH*, 44 DV XXL, and 36 DV

Hot

(black)

Common

(white)

Ground (green)

Rheostat

Junction Box

Hot

(black)

Common

(white)

Ground (green)

Blower

Assembly

1Follow the directions below to wire the blower box.

a

Remove the cover from the blower box.

Phillips

Screwdriver

b

Standard

Screwdriver

Insert sheathed cable through the cable clamp. After the wires have been connected tighten the clamp to secure the cable.

c

Attach the hot (black) and common (white) wires to the

leads coming from the wires (use wire nuts).

Secure the ground wire to the ground stud inside the d blower box by tightening the included nut over the

ground wire. Re-attach the cover removed in step "a".

Ground Wire

Travis Industries

4070201

100-01182_002

Page 62
Image 62
North Star Wiring Instructions, Wiring Diagram - 864 HH*, 44 DV XXL, and 36 DV, Wiring Diagram -864TRV, 4070201