54 Finalizing the Installation (for qualified installers only)

5Replace the firebox components. Install the logs and embers. Replace the glass.

6Remove the regulator from the front of the gas control valve. Replace with the propane regulator, using the new gasket and screws included with the regulator. NOTE: Leak test this area after the heater is installed, gas is connected, and the main burner is lit.

7Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve. Check the pilot (see the illustration below. Adjust if necessary.

WARNING: When lighting or re-lighting the pilot, the glass must be removed (see page 45).

a

Remove and discard the three screws using a slotted screwdriver of Torx T-20.

Slotted

Screwdriver

(or T-20 Torx)

c

Install the LP regulator. Use the screws included with the LP regulator. Tighten to approximately 25 Lbs. torque.

Slotted

Screwdriver

(or T-20 Torx)

b

Remove and discard the regulator, diaphram, spring and center post.

NOTE: Make sure the regulator gasket is correctly aligned before installation.

d

Place the LP label on the base of the fireplace near the gas control valve.

To adjust the pilot flame, turn this screw (NOTE: if totally

 

The pilot flame must contact the thermocouple and

unscrewed gas will come out of this port). Clockwise

 

thermopile (see the illustration below). Adjust the pilot up or

lowers the flame while counter-clockwise raises it.

Standard

down as necessary.

 

Screwdriver

 

Travis Industries

4070201

100-01182_002

Page 54