North Star 864 HH Termination Requirements, Installation for qualified installers only, 4070201

Models: 864 HH

1 68
Download 68 pages 62.14 Kb
Page 31
Image 31
Termination Requirements

 

 

Installation (for qualified installers only)

31

 

 

Termination Requirements

 

 

 

NOTE: Measure all clearances from the nearest edge of the exhaust hood.

Roof

 

A

Minimum 9" clearance from any door or window

 

Surface

 

B

Minimum 12" above any grade, veranda, porch, deck or balcony

 

 

 

C

Minimum 3-3/8" from outside corner walls

11” Min.

 

Roof

 

D

Minimum 0" from inside corner walls

6” Min. Eaves

 

 

 

EMinimum 11" clearance below unventilated soffits or roof surfaces

Minimum 18" clearance below ventilated soffits

Minimum 6" clearance below roof eaves

NOTE: Vinyl surfaces require 24"

FMinimum 18" clearance below a veranda, porch, deck or balcony (must have two open sides)

GMinimum 48" clearance from any adjacent building

HMinimum 84" clearance above any grade when adjacent to public walkways or driveways NOTE: may not be used over a walkway or driveway shared by an adjacent building

IMinimum 48" clearance from any mechanical air supply inlet

JMinimum 36" clearance above and 48” below and to the sides of non-mechanical air supply inlet

KMinimum 36" from the area above the meter/regulator (vent outlet)

L Minimum 36" from the meter/regulator (vent outlet)

M Minimum 24” above the roof line (for vertical terminations)

NMinimum 24” horizontal clearance to any surface (such as an exterior wall) – for vertical terminations

Manual background E

NManual background

Manual backgroundManual background M

E

A

K

G Manual backgroundManual backgroundManual backgroundManual background A

F

D Manual backgroundManual background C I

L

B

NOTE: Measure clearances to the nearest edge of the exhaust hood.

E

J

H

Use the vinyl siding standoff (#950) when installing on an exterior with vinyl siding.

Vent termination must not be located where it will become plugged by snow or other material.

Venting termination shall not be recessed into a wall or siding.

These clearances meet UMC-1994 code standards.

© Travis Industries

4070201

100-01182_002

Page 31
Image 31
North Star 864 HH installation manual Termination Requirements, Installation for qualified installers only, 4070201