Air Shutter Adjustment

44 Finalizing the Installation (for qualified installers only)

8. Check the air shutter following the directions below.

Air Shutter Adjustment

Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.

Correct

Not Enough Air

Too Much Air

Flames should be blue at the

If the flames are over 14" tall or sooty on

If the flames are all blue and

base, yellow-orange on the top.

the ends, open the air shutter.

short, close the air shutter.

Air Shutter Adjustment

The air shutters may be adjusted while the burner is on (take care to prevent contacting the burner area).

There are two air shutters on this fireplace - adjust both air shutters to obtain the correct flame.

Front Air Shutter

Rear Air

Move the controls left or right until the flame looks correct. The rear air shutter affects the rear portion of the burner, the front air shutter the front portion of the burner. Pushing to the left gives the flame less air, making it more orange. Pushing to the right gives the flame more air, making it more blue.

Control

Shutter Control

NOTE: If the air control is all the way open, yet the flames remain sooty, shut off gas to the fireplace and contact a qualified gas service technician.

LESS

MORE

AIR

AIR

 

NOTE: The logs must be installed correctly to monitor the flame while adjusting the air shutter.

9.Turn the flame adjust knob to its highest position - the firebox. Check the flame on low position. The flames the heater does not work correctly, contact your Travis

flames should not contact the top of the

should burn off of each burner hole.

If

dealer for a remedy.

 

10.Give this manual to the home owner for future reference and fully explain operation of this heater. For comprehensive operating and maintenance instructions, refer to the Owner's Manual (part # 100-01181).

ACID WASH WARNING: Before installing the faceplate, make sure any masonry that has been treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash (muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia solution, the plated face may develop a permanent tarnish when the acid evaporates over time. Contact your dealer if uncertain your facing has been properly neutralized.