North Star 864 HH Optional Wall-MountedRheostat, Accent Light Operation, Travis Industries

Models: 864 HH

1 68
Download 68 pages 62.14 Kb
Page 66
Image 66
Optional Wall-Mounted Rheostat

66

Optional Equipment (for qualified installers only)

Optional Wall-Mounted Rheostat

NOTE: Many areas require all wiring to be installed by a qualified electrician. Check with your local building official for any requirements in your area.

1Remove the rheostat from the rheostat assembly.

2Detach the three wires leading from the rheostat (secured with wire nuts). Attach the rheostat assembly to the fireplace (see the illustration on the previous page). Attach the quick connects from the rheostat to the quick connects from the accent light assemblies (see the illustration on the previous page).

3Attach three suitable wires (insulated & sheathed) to the rheostat. Install the rheostat into a junction box at the remote location. Run the wire from the junction box to the fireplace. Use the included wire clamp to secure the wiring as it passes through the fireplace (see the illustration below).

4Connect the three wires from the rheostat to the three wires on the wiring harness disconnected in step 2 (use the included wire nuts). Plug the rheostat assembly into the receptacle inside the fireplace.

Rheostat (removed from rheostat assembly)

Knob (included)

Junction Box

Wire Clamp (included)

Rheostat

Assembly

A 7/8” diameter hole is provided on this cover plate (both sides). If this hole is already used for a gas inlet, you can drill an additional 7/8” hole in this cover plate.

Accent Light Operation

NOTE:

The accent light responds best when turned to high, then turned down to the desired light level.

 

OFF

 

LOW

 

HIGH

Turn the dial all the

Turn the dial 180°

 

The high position

way counter-clockwise

clockwise until the light

 

is all the way

until it clicks off.

begins to glow.

 

clockwise.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Travis Industries

4070201

100-01182_002

Page 66
Image 66
North Star 864 HH Optional Wall-MountedRheostat, Accent Light Operation, Optional Equipment for qualified installers only