North Star Extra Room Power Heat Duct sku, Special Instructions for 864 HH, New Wire Hook-Up

Models: 864 HH

1 68
Download 68 pages 62.14 Kb
Page 57
Image 57
Extra Room Power Heat Duct (sku 98500769)

Optional Equipment (for qualified installers only)

57

Extra Room Power Heat Duct (sku 98500769)

Special Instructions for 864 HH

Newer 864 HH fireplaces (SN 3407-001010 or greater) have an improved wiring harness and removable heat shields below the heat duct connections. The wiring harness is now routed through the snap disk, allowing the power heat duct to be turned on and off by the fireplace (see “Wiring Instructions” on page 62). An additional knock-out was added to the fireplace to allow for the electrical line to be routed to the power heat duct (see below). The removable heat shields allow more heat to be routed to the power heat ducts (see below for details).

New Wire Hook-Up

A knock-out is provided on the left side of the fireplace for routing the sheathed cable (romex) from the inside of the firebox to the power heat duct. Use the strain relief (included with the power heat duct) to secure the cable.

 

Molex Connector

 

(attached to the

Cable to

wiring harness on

Power Heat

the fireplace)

Duct

 

Molex Connector (included with heat duct kit) - use wire nuts to attach to the cable.

New Removable Heat Shield (improves heat output to power heat duct)

Remove and discard the power heat

Remove and discard the circular cover
duct cover plate (one or both sides).
plate attached to the heat shield.

© Travis Industries

4070201

100-01182_002

Page 57
Image 57
North Star Extra Room Power Heat Duct sku, Special Instructions for 864 HH, New Wire Hook-Up, 4070201