Installation (for qualified installers only)

Minimum Framing Dimensions - Rear Vent Configuration

HINT: place the fireplace so the center line is at least 5" from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications)

Minimum 49” Fireplace

Enclosure Height

Route the

electrical line to

a position to the

Included Firestop (required)

Part # 93006094

Vent Clearances (8" dia. Vent):

1" to the sides, 1" below, and 3" above the vent to combustibles.

Center of Rear Vent

30-3/4"

38"

25-3/4"

left rear of the

fireplace.

38-1/2"

41-1/4"Manual background 20"

The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace.