XPak 85

 

XPak 120

Boiler flue gas connection

in

2 3/8

 

2 3/8

 

mm

60

 

60

Combustion air connection outer dia.

in

4

 

4

 

mm

100

 

100

Free fan unit feed pressure

in w. c.

0.26

 

0.18

 

Pa

65

 

45

Flue gas mass flow rate at rated full load (A)

lbs/hr

90.39

 

123.17

 

kg/hr

41

 

55.87

Flue gas mass flow rate at rated full load (E)

lbs/hr

88.89

 

121.18

 

kg/hr

40.32

 

54.97

Flue gas mass flow rate at rated partial load (A)

lbs/hr

26.58

 

28.48

 

kg/hr

12.06

 

12.92

Flue gas mass flow rate at rated partial load (E)

lbs/hr

25.08

 

27.99

 

kg/hr

11.88

 

12.70

Condensate flow rate (A) at max - 122/86 °F (50/30°C) USG/hr

0.37

 

0.41

 

ltr/hr

1.41

 

1.56

Condensate flow rate (A) at min. - 122/86 °F (50/30°C) USG/hr

0.13

 

0.16

 

ltr/hr

0.48

 

0.6

Flue temperature at boiler return temp. 86°F/30°C

°F

186.0

 

170.0

at full load (A)

°C

86.0

 

77.0

Flue temperature at boiler return temp. 86°F/30°C

°F

163.0

 

165.0

at partial load (A)

°C

73.0

 

74.0

Flue temperature at boiler return temp. 140°F/60°C

°F

194.0

 

186.0

at full load (A)

°C

90.0

 

86.0

 

 

 

 

 

Max flues length de-rate less 2%

 

 

 

 

Max length horizontal coaxial 60/100 mm

ft

6.5

 

6.5

 

m

2

 

2

Max total length 2 pipe 3” (80 mm) (air + flues)

ft

40+40

 

16+16

 

m

12+12

 

5+5

Max flues length de-rate less 5%

 

 

 

 

Max length horizontal coaxial 60/100 mm

ft

26

 

26

 

m

7.8

 

7.8

Max total length 2 pipe 3” (80 mm) - (air + flues)

ft

130+130

 

115+115

 

m

40+40

 

35+35

Minimum Clearances To Combustibles

 

 

 

 

Top - front - rear

in

 

0 - 0 - 0

 

mm

 

0 - 0 - 0

Left - right - vent pipe

in

 

0 - 0 - 0

 

mm

 

0 - 0 - 0

Recommended Minimum Service Clearances

 

 

 

 

Top - front - rear

in

12 - 24 - 0

 

mm

300 - 600 - 0

Left - right

in

 

1 - 1

 

mm

 

25 - 25

Pipe Connections

 

 

 

 

Gas supply connection (shut off valve)

in

3/4 NPT - female

Boiler in connection

in

3/4 NPT - male

Boiler out connection

in

3/4 NPT - male

Pressure relief valve

in

3/4 NPT - female

Condensate connection diameter (rubber flexible)

in

0.825 female

 

mm

21 female

Boiler drain valve - open-ended wrench dimension

in

 

7/16

 

mm

 

11

Boiler Dimensions And Weight

 

 

 

 

Height x Width x Dept

in

30.7 x 15.75 x 14.1

 

30.7 x 17.7 x 14.1

 

mm

780 x 400 x 358

 

780 x 450 x 358

Weight net

lbs

73

 

80

 

kg

33

 

36

Components

 

 

 

 

Burner

 

Stainless Steel

Main heat exchanger

 

ASME approved extruded aluminum

Gas valve

 

 

SIT 848

Pump

 

Groundfos UPM 15-52

 

Groundfos UPM 15-62

Pressure relief valve

 

Watts M350 - M2 ASME approved

Fan

 

MVL RG 128

3-way valve for DHW tank (field supply)

 

Honeywell VC6011 + VCZMK6000

Injector Natural Gas (A) Ø

 

0.20 inch (5.1 mm)

 

0.26 inch (6.7 mm)

Injector LPG (E) - black coated Ø

 

0.15 inch (3.9 mm)

 

0.19 inch (5.0 mm)

notes

*See jumpers configurations for heating temperature range setting

**If the gas supply pressure exceeds the maximum gas supply pressure value, a separate gas pressure regulator must be installed upstream of the heating system.

11

Page 11
Image 11
Raypak 120 XPak, Max flues length de-rate less 2%, Max flues length de-rate less 5%, Minimum Clearances To Combustibles

120, 85 specifications

The Raypak 120,85 is a prominent model in the realm of pool and spa heating solutions, designed to deliver unmatched efficiency and performance. Renowned for its robust features and innovative technologies, the Raypak 120,85 stands out as a reliable choice for homeowners seeking to maintain the perfect water temperature in their pools and spas.

One of the primary characteristics of the Raypak 120,85 is its impressive heating capacity. With a total output of 120,000 BTUs, this heater quickly and efficiently warms up water, ensuring that users can enjoy comfortable swimming conditions regardless of the outdoor temperature. The 85 indicates its ability to deliver consistent performance even in cooler climates, making it an adaptable option for various geographical locations.

The Raypak 120,85 is equipped with a state-of-the-art, copper fin tube heat exchanger, which provides superior heat transfer efficiency. This technology enhances the heater's ability to warm water rapidly while maintaining energy efficiency. Additionally, the copper material is known for its durability and resistance to corrosion, ensuring a long lifespan for the heat exchanger.

Another key feature of the Raypak 120,85 is its electronic ignition system. This innovation eliminates the need for a standing pilot light, which not only saves energy but also enhances safety by reducing the risk of gas leaks associated with traditional ignition systems. The electronic ignition provides precise control, ensuring a reliable start each time.

The Raypak 120,85 also boasts a digital display control panel, allowing users to easily monitor and adjust the water temperature settings. This intuitive interface provides accurate readings and simplifies the operation, making it accessible for all users, regardless of their technical expertise.

Furthermore, this heater is designed with a compact footprint, making it suitable for a variety of installation spaces, whether it’s in a pool equipment area or near a spa. Its robust build quality and weather-resistant design ensure that it can withstand the elements, making it a durable and long-lasting investment.

In summary, the Raypak 120,85 combines advanced heating technology, robust construction, and user-friendly features. With its high BTU output, efficient heat exchanger, electronic ignition, and digital controls, it represents a top-tier option for anyone seeking reliable and effective heating solutions for pools and spas. Whether for leisure or relaxation, the Raypak 120,85 promises to deliver an optimal swimming experience, season after season.