TECHNICAL DATA |
|
|
| Tab. 1 |
|
|
|
|
|
|
| XPak 85 |
| XPak 120 |
Input - Output |
|
|
|
|
Input - (0 - 2000 ft / 0 - 610 m) | Btu/hr | 25,600 - 87,000 |
| 27,300 - 119,500 |
| kW | 7.5 - 25.5 |
| 8.0 - 35.0 |
Input - (2000 - 4500 ft / 610 - 1375 m) | Btu/hr | 25,600 - 82,900 |
| 27,300 - 114,300 |
| kW | 7.5 - 24.3 |
| 8.0 - 33.5 |
Output (176°F - 86°F / 80°C - 30°C) | Btu/hr | 25,200 - 76,600 |
| 26,600 - 108,300 |
| kW | 7.4 - 22.5 |
| 7.8 - 31.7 |
Energy Guide |
|
|
|
|
AFUE | % | 91.8 |
| 92.6 |
Gas |
|
|
|
|
Gas supply pressure Natural Gas (A) | in w. c. |
| 6.82 | |
| kPa |
| 1.70 | |
Min. gas supply pressure Natural Gas (A) | in w. c. |
| 3.5 | |
| kPa |
| 0.87 | |
Max. gas supply pressure Natural Gas (A)** | in w. c. |
| 10.5 | |
| kPa |
| 2.62 | |
Gas supply pressure LPG (E) | in w. c. |
| 11 | |
| kPa |
| 2.75 | |
Min. gas supply pressure LPG (E) | in w. c. |
| 8 |
|
| kPa |
| 1.99 | |
Max. gas supply pressure LPG (E)** | in w. c. |
| 13 | |
| kPa |
| 3.24 | |
Gas Rate max natural gas (A) | ft3/hr | 87.77 |
| 121.01 |
| sm3/hr | 2.49 |
| 3.43 |
Gas Rate min natural gas (A) | ft3/hr | 26.14 |
| 28.01 |
| sm3/hr | 0.74 |
| 0.79 |
Gas Rate max LPG (E) | lbs/hr | 4.02 |
| 5.55 |
| kg/hr | 1.82 |
| 2.52 |
Gas Rate min LPG (E) | lbs/hr | 1.20 |
| 1.28 |
| kg/hr | 0.54 |
| 0.58 |
System Data |
|
|
|
|
Minimum relief valve capacity | lbs/hr | 87 |
| 119.50 |
Maximum operating pressure | p.s.i. |
| 45 | |
| bar |
| 3.1 | |
Minimum operating pressure | p.s.i. |
| 6.52 | |
| bar |
| 0.45 | |
Recommended system pressure | p.s.i. |
| 15 | |
| bar |
| 1 |
|
Boiler max flow rate (ltr/hr) | GPM | 5.72 |
| 6.2 |
| ltr/hr | 1,300 |
| 1,400 |
Pump residual head at max flow rate | in w. c. | 60.22 |
| 44.11 |
| mbar | 150 |
| 110 |
Primary water content | CAN G | 0.70 |
| 0.84 |
| USG | 0.85 |
| 1.0 |
| ltr | 3.2 |
| 3.8 |
Boiler Water Temperature |
|
|
|
|
Adjustable high limit range - high temp. (radiators heating)* °F |
| 104 - 176 | ||
| °C |
| 40 - 80 | |
Adjustable high limit range - low temp. (space heating)* | °F |
| 68 - 113 | |
| °C |
| 20 - 45 | |
DHW production - set point | °F |
| 95 - 140 | |
| °C |
| 35 - 60 | |
Max boiler temperature | °F |
| 194 | |
| °C |
| 90 | |
Electric Data |
|
|
|
|
Electric rate voltage | V - Hz |
| 120 - 60 | |
Current less than | A | 1.19 |
| 1.25 |
Electric consumption (pump included) | W | 133 |
| 141 |
Electrical protection rating | IP |
| IPX5D | |
Fuses | A - VAC |
| 4 - 250 | |
Flue Gas Values |
|
|
|
|
CO2 setting natural gas (A) | % |
| 8.5% | |
CO2 setting LPG (E) | % |
| 10.0% | |
NOx @ max (A) | ppm | < 20 |
| < 20 |
NOx @ min (A) | ppm | < 15 |
| < 15 |
CO @ max (A) without air | ppm | < 135 |
| < 170 |
CO @ min (A) without air | ppm | < 15 |
| < 25 |
NOx @ max (E) | ppm | < 20 |
| < 20 |
NOx @ min (E) | ppm | < 15 |
| < 20 |
CO @ max (E) without air | ppm | < 200 |
| < 220 |
CO @ min (E) without air | ppm | < 40 |
| < 35 |