Domestic hot water (with connection to an external water tank with probe)
The function starts if the temperature measured by the water tank probe falls below 40°F (4°C). In this mode, a heat demand is generated and the burner ignites at minimum power. This is maintained until the temperature of the delivery water reaches 95°F (35°C).
NOTICE: During the freeze protection mode, AF flashes on the display (Fig. 56)
-circulator
-move the function selector to
-turn the main system switch to “off”
8.INDICATOR LEDS AND FAULTS
Green indicator LED (Fig. 52)
Off = boiler on
On = burner on, the boiler works regularly.
Red indicator LED (Fig. 53)
Stop: just the fault code flashes on the digital display.
Block: the red indicator LED lights up and the fault code flashes on the digital display.
The fault code is not displayed in the OFF/RESET () mode. To
display it, move the function selector to ,
or
F . During combustion analysis and the freeze protection mode, instead, it is displayed. To reset the boiler, turn the function selector to
(OFF/ RESET) and then move it to be required position (Fig. 47). If the boiler still doesn’t work, call in the local Service Technician.
AB C DE
GF
APressure gauge
BGreen led
C
DRed led
ETemperature selector space heating
FMode selector switch
GTemperature selector Domestic Hot Water*
* The parts of the manual refering to the DHW circuit should be only considered if a indirect water tank with sensor is installed, case B (Fig. 61)