Raypak 120 Danger, What to do if you smell gas, Observe these instructions as general warnings

Models: 120 85

1 68
Download 68 pages 52 Kb
Page 5
Image 5
What to do if you smell gas

DANGER

if flammable gas explodes.

Beware if you smell gas: there may be an explosion hazard!

Warning: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other boiler.

What to do if you smell gas

-Do not try to light any boiler.

-Do not touch any electrical switch; do not use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Observe these instructions as general warnings:

Chemicals used to clean the system and/or inhibit corrosion must be pH neutral, i.e. they should ensure that the level of the pH in the system water remains neutral.

Premature failure of certain components can occur if the pH level in the system water is out of normal levels.

Raypak recommends that an inhibitor - suitable for use with aluminum heat exchangers - is used to protect the boiler and system from the effects of corrosion and/or electrolytic action. The inhibitor must be administered in strict accordance with the manufacturers instructions.

A properly sized expansion tank must be installed in the boiler system. No valve is to be placed between the boiler and the expansion tank.

When the boiler has been filled for the first time or the system has been drained and refilled, it will be necessary to purge any air that may have become trapped within the appliance heat exchanger.

NOTE: Glycol in the system must not exced 40%.

Observe these instructions for space heating water:

Thoroughly flush the system prior to filling.

Only use untreated main water to fill and top off the system.

Do not use water softners in the system.

Do not use inhibitors or other additives!

The maximum permissible flow rate of the XPAK 85 this is 5.7 GPM (1,300 ltr/hr), for the XPAK 120 is 6.2 GPM (1,400 ltr/hr).

When using oxygen-permeable pipes, e.g. for floor heating systems, you must separate the system using heat exchangers. Unsuitable heating system water promotes the formation of sludge and corrosion. This may damage the heat exchanger or affect its operation.

A properly sized expansion tank must be installed in the boiler system.

Tools, materials and additional equipment

For the installation and maintenance of the boiler you will need the standard tools for space heating, gas and water fitting.

In addition, a handtruck with a fastening belt is very useful.

Disposal

Dispose of the boiler packaging in an environmentally sound manner.

Dispose of components of the heating system (e. g. boiler or control device), that must be replaced, by handing them in to an authorized recycling facility.

5

Page 5
Image 5
Raypak 120, 85 manual Danger, What to do if you smell gas, Observe these instructions as general warnings